NXC  Version 1.2.1 r5
 All Data Structures Files Functions Variables Groups Pages
#define RegIValueField   11

Integral field.

Contains the integral constant for the PID motor controller. Read/write. This field specifies the integral term used in the internal proportional-integral-derivative (PID) control algorithm. Set UF_UPDATE_PID_VALUES to commit changes to RegPValue, RegIValue, and RegDValue simultaneously.